SECTION 099000

PAINTING AND COATING


This specification specifies Best Commercial Grade paints and coatings and is a consensus document that replaces the Master Painter Institute (MPI) Product Listings.

Conformance to MPI Approved Products is coincidental. However a link to MPI Product Listing is included in hidden text for many products. MPI Web Site: http://www.paintinfo.com

Approved Products by MPI do not include complete listings for each manufacturer. Products are not necessarily equivalent in performance and general quality. Levels of quality set by MPI have forced some manufacturers to lower product quality in order to meet this bar in order to remain competitive. High cost and time delays for testing by MPI has resulted in incomplete test results and delays in listing hybrid and other innovative product technologies.

Specification attempts to include a full product line of commercial quality paints from each manufacturer. Premium products, designed for the home-owner, are not included because equivalency varies cannot be established between manufacturers.

Acceptance of listed manufacturers is dependent upon availability of locally available, manufacturer employed, architectural product representative who are independent from paint distributors, available to aid in technical advice, and able to evaluate and perform other field services.

Consult with architectural product representatives to obtain updates of equivalent products and as needed to maintain a full product line for each manufacturer.

Check MPI, GreenGuard, and GreenSeal for LEED projects. These are not comprehensive lists but are being developed. Web Site http://www.greenseal.org / http://www.greenguard.org


GENERAL

SUMMARY


Edit to conform to meet project requirements.


Section Includes:

Surface preparation.

Field applied primers and sealers.

Field applied coatings and paints.

Painting and coating schedule.

Shop Preparation and Primers for Metal: Specified Section 055000 - Metal Fabrication.

[Alternates: Refer to Section 012300- Alternates for effect on work of this Section.]


Edit related Sections to those referenced in body of specification section.


Related Requirements: Affected by this Section, include but are not limited to following:

Section 033000 - Cast-In-Place Concrete

Section 042200 - Concrete Masonry Units

Section 051200 - Structural Steel Framing

Section 052119 - Open Web Steel Joists

Section 053100 - Steel Deck

Section 055000 - Metal Fabrications

Section 055100 - Metal Stairs

Section 055200 - Handrails and Railings

Section 062000 - Finish Carpentry and Millwork

Section 061800 - Glue Laminated Structural Units

Section 074646 - Fiber Cement Siding

Section 078400 - Firestopping

Section 079200 - Joint Sealants

Section 081113 - Hollow Metal Doors and Frames

Section 083113 - Access Doors and Frames

Section 083313 - Overhead Coiling Doors and Counter Shutters

Section 092400 - Portland Cement Plaster

Section 092900 - Gypsum Board

Section 061643 - Gypsum Sheathing Board: Soffits

Section 092117 - Shaft Wall

Section 096466 - Resilient Athletic Wood Flooring

Section 099713 - Steel Coatings

Division 22 - Plumbing

Division 23 - Heating, Ventilating, and Air Conditioning

Division 26 - Electrical

REFERENCES


Edit reference standards to those referenced in body of specification section.


Reference Standards: Conform to provision of Section 014219.

ASTM International (ASTM):

ASTM D523 - Standard Test Method for Specular Gloss.

ASTM D6763 - Standard Guide for Testing Exterior Wood Stains.

[ASTM D7489 - Standard Practice for Evaluating Touch-Up Properties of Architectural Coatings under Various Environmental Conditions]

[ASTM D7514 - Standard Test Method for Evaluating Ink Stainblocking of Architectural Paint Systems by Visual Assessment]

ASTM D5324 - Standard Guide for Testing Water-Borne Architectural Coatings.

ASTM D6386 - Standard Practice for Preparation of Zinc (Hot-Dip Galvanized) Coated Iron and Steel Hardware Surfaces for Painting

Green Seal (GS). http://www.greenseal.org

GS-11 - Green Seal Standard for Paints and Coatings, May 20, 1993 1st edition.

GC-03 - Green Seal Standard for Anti-Corrosive Paints, January 7, 1997 2nd Edition

South Coast Air Quality Management District (SCAQMD): http://www.aqmd.gov/rules/reg/reg11/r1113.pdf

SCAQMD Rule 1113 - Architectural Coatings, effective January 1, 2004

[The Master Painters Institute (MPI): Tel 1-888-674-8937, Fax 1-888-211-8708, Email [email protected] , Web Site http://www.paintinfo.com .]

[MPI Approved Product List.]

[MPI Architectural Painting Specification Manual.]

SSPC, The Society for Protective Coatings: Web Site http://www.sspc.org

SSPC-SP-1: Surface Preparation Specification No.1, Solvent Cleaning.

SSPC-SP-2: Surface Preparation Specification No.2, Hand Tool Cleaning.

SSPC-SP-3: Surface Preparation Specification No.3, Power Tool Cleaning

[SSPC-SP- 6: Surface Preparation Specification No. 6, Commercial Blast Cleaning]

[SSPC-SP-10: Surface Preparation Specification No. 10, Near White Blast Cleaning.]

[United States Environmental Protection Agency (EPA):

EPA 40 CFR Part 59 (AD-FRL-6149-71] RIN 2060 - National Volatile Organic Compound Emission Standards for Architectural Coatings, Final Rule, Federal Register / Vol. 63, No.176, September 11, 1998/Rules and Regulations.]

Web Site http://www.epa.gov/ttn/uatw/183e/aim/fr1191.txt

US Green Building Council (USGBC): http://www.usgbc.com

LEED 2009 for New Construction and Major Renovations

ADMINISTRATIVE REQUIRMENTS

Pre-Installation Conference: Arrange under provisions of Section 013119.

Attendance: Contractor, painting subcontractor, Owner, Architect, manufacturer’s technical representative, [Painting Inspection Agency], and others as requested to attend.

Meeting Time: Minimum 2 weeks before beginning work of this Section and work of related Sections affecting work of this Section, and as necessary to meet Project Schedule.

Location: Project Site.

SUBMITTALS

Submit under provisions of Section 013300.

Product Data: Provide in the same order as scheduled by this Section:

Manufacturer’s Product Data Sheets for each product.

Performance features, substrate recommendations, primer recommendations (where required), and product limitations.

Recommended dry film thickness.

Solids by weight.

Solids by volume.


Following Label analysis is worth enforcing as a means to evaluate quality of paint products which often conceal solids content by using fillers and additives to make a product appear to have higher solids and more active resin and pigments than is actually the case. Manufacturers will resist submitting this and is a cause for rejection of suspicious and substitute products.


Product/Label Analysis for paint products:

Pigment and vehicle percentages by weight.

Pigment composition analysis, including fillers in percent by weight.

Vehicle composition analysis, including resins, solvents, and additives by weight.

Material Data Safety Sheets (MSDS) :

Solvents, driers, additives, and fillers.

Volatile organic compounds (VOC) emissions in grams per liter.

Chip Color Samples: Manufacturer’s complete selection.

Paint Drawdown Color Samples: Size not less than 8 inch by 10 inch draw-down for each color selected for final acceptance prior to beginning work.

Label back of each drawdown with manufacturer, product, color name and number, and gloss level.

Furnish additional samples as required for acceptance of colors, finishes, and textures.

Retain approved samples for reference.


Following is a placeholder for Sustainable Design Submittals and requires editing to current edition of certifying organization including US Green Building Council - USGBC LEED, Green Building Initiative (GBI) - Green Globes, International Living Future Institute (ILFI) - Living Building Challenge, Washing Sustainable Schools Protocol (WSSP), or as applicable.


[SUSTAINABLE DESIGN SUBMITTALS

Submit under provisions of Section 033300.

Sustainable Design Certifications: Signed by manufacturer authorized representative, as applicable, for documentation of products contributing toward LEED Credits in conformance to Section 018113.

MR Credit 5, Regional Materials:

List products that that have been extracted, harvested or recovered, as well as manufactured, within 500 miles of the project site.

If only a fraction of a product or material is extracted, harvested, or recovered and manufactured locally, then only that percentage (by weight) can contribute to the regional value.

Record volume and cost of materials that meet this requirement.

Indoor Environmental Quality (IEQ):

IEQ Credit 4.2, Low Emitting Materials – Paints and Coatings:

Product data for field applied interior paints and coatings. Include technical data as required to verify VOC levels.

Sustainable Products Cost Data: Submit cost for certified sustainable product submittal. Exclude cost of labor and equipment to install products.]

CLOSEOUT SUBMITTALS

Conform to provisions of Section 017824.

Maintenance Data: Product data sheets, manufacturer’s application instructions, MSDS, product color name and number, cleaning instructions, and spot repair and repaint instructions.

Invoices and other data as necessary to verify quantities of each paint product suitable for coverage in conformance to manufacturer’s instructions.

[MAINTENCE MATERIAL SUBMITTALS


Verify if Owner wants this.


Submit in conformance to Section 017700.

Minimum one gallon of each paint and coating type and color.

Identify each container as to manufacturer, product, color name, and number with minimum 5 inch press type. Tape over with clear tape.

Include manufacturer instructions and MSDS for each product submitted

Turn over to Owner prior to project completion. Obtain signed receipt.]

QUALITY ASSURANCE

Manufacturer Qualifications:

Manufacturer Employ full time locally available architectural product representative, technical field representative, testing equipment, and services as necessary to perform inspections and to determine compliance with manufacturer’s instructions and provisions of Contract Documents.

Applicator Qualifications:

Able to document minimum 10 years continuous experience in commercial quality projects of similar type and scope.

Employ qualified journeymen painters with apprentices under direction of qualified journeymen, conforming to trade regulations.


Painting inspection is seldom specified. Where this is a requirement, specify additional requirements under Section 014324 -Painting Inspection Services.


[Painting Inspection: Conform to provisions of Section 014324.

Painting Inspection Agency: Acceptable to Owner and Accredited Quality Assurance Association.

Attend preconstruction meeting, make inspection of substrates prior to application of paints and coatings, make intermittent inspections, and make final inspection based on requirements of Architectural Painting Specification Manual. .

Make report to Architect indicating defects and action required where inspection indicates non-compliance.

Contractor: Notify Painting Inspection Agency one week prior to beginning work and assist painting inspection agency in performing inspection services. ]


Verify following with prevailing codes and authorities having jurisdiction. SCAQMD is no longer required for LEED. This may be referenced in LEED NC, CS, and CI Version 3.0.


Sustainability Standards Certifications:

Architectural Paints, Coatings, and Primers Applied to Interior Walls and Ceilings: Do not exceed Volatile Organic Compound (VOC) content limits established in Green Seal Standard GS11, Paints, First Edition, May 20, 1993.

Anti-Corrosive Coating and Anti-Rust Paints applied to interior Ferrous Metal Substrates: Do not exceed VOC content limits established in Green Seal Standard GC-03, anti-Corrosive Paints, 2nd Edition, January 7, 1997

Clear Wood Finishes, Floor Coatings, Stains, and Shellacs Applied to Interior Elements: Do not exceed VOC content limits established in South Coast Air Quality Management District (SCAQMD) Rule 1113, Architectural Coatings, rules in effect on January 1, 2004.

Field Samples: Provide under provisions of Section 014300.

Minimum three 10 square foot area field sample for each accepted color and substrate type. Provide as a step-down field sample, showing each step of system, including surface preparation.

Locate as accepted by Architect.

Protect and retain accepted field samples as standard of quality for work of this Section.

Accepted field samples may be incorporated into finished work.

DELIVERY, STORAGE, AND HANDLING

Conform to provisions of Section 016510 and manufacturer's instructions.

Deliver in unopened, sealed containers, bearing manufacturer's original labels with manufacturer’s brand name, product name and number, color designation, surface preparation, mixing and reducing instructions, coverage, drying time, clean-up instructions, MSDS, and VOC content. Include invoice statements showing quantities of each paint product. Submit to Architect upon request as a means to verify quantities suitable for coverage.

Store and utilize paint in original containers bearing manufacturer’s label for ease of identification. Do not put paint in containers bearing labels for other products.

Store at ambient temperature between 45 degrees F and 90 degrees F. Store and mix material outside building.

Take special safety precautions against hazards from toxic and flammable materials.

Place paint and solvent contaminated cloths and materials, subject to spontaneous combustion, in containers and remove from job site each day.

FIELD CONDITIONS

Environmental Requirements: Do no apply paints and coatings at surface and air temperatures below 50 degrees F, except as specified by this Section or as instructed or accepted by manufacturer.

Weather: Do not apply exterior coatings when precipitation is predicted or appears imminent.

Ventilation: Maintain continuous air exchange ventilation. Move moisture, odors, and fumes from painting to outside of building.

Illumination: Maintain lighting level of 50 foot candles measured at mid height at substrate surfaces.

WARRANTY

Conform to Warranty provisions specified Section 017836.

Manufacturer: 5 year materials Warranty.

PRODUCTS

MANUFACTURERS

Benjamin Moore:

Tel 1-800-642-5678 Ext 2217, Fax (503) 263-3849, Cellular (503) 318-8046 Email [email protected] (Randy Tessman, Architectural Rep)

Web Site http://www.benjaminmoore.com /

Coronado Paint.

Tel 1-800-642-5678 Ext 2217, Fax (503) 263-3849, Cellular (503) 318-8046 Email [email protected] (Randy Tessman, Architectural Rep)

Web Site http://www.coronadopaint.com /

Kelly-Moore Paint Company / RPM Company, Rust-Oleum.

Cell (206) 261-1958, Email [email protected] (Mike Murphy, Architectural Representative CSI, CDT, NACE 1)

Web Site http://www.kellymoore.com

Miller Paint Company

Cell (206) 261-1958, Email [email protected] (Mike Murphy, Architectural Representative CSI, CDT, NACE 1)

Cell (425) 457-0983, Office (425) 248-4950, Email [email protected] (Holly Davidson, Outside Sales)

Web Site http://www.millerpaint.com

PPG Architectural Coatings

Cell (206) 354-0179, Email terry.decker@ PPG.com (Terry Decker, NACE1, LEED AP, CDT, Architectural Manager Northwest US and Western Canada )

Web Site http://www.ppgac.com

Rodda Paint Company / Cloverdale Paint:

Cell (206) 396-7074, Tel (206) 652-0445, Fax (206) 652-0565, Email [email protected] (Jeff McIntyre, Architectural Sales Rep)

Web Site http://www.roddapaint.com /

Sherwin-Williams Company.

Cell (425) 417-1765, Email [email protected] (Brian Keil, CSI CCPR, NACE CPI-1)

Tel 1-800-321-8194 (Technical Hot Line).

Web Site http://www.sherwin-williams.com /

Tnemec Company, Inc.

Tel (206) 762-5755, Cell Email [email protected] (Torin Mowbray, CSI, TNW, Inc.) Web Site http://www.tnemec.com

PPG, Sikkens Decorative Coatings.

Tel (425) 876-2131, Email [email protected] Patrick Eelnurme)

Technical Support- 1-866-745-5367

Web Site http://www.nam.sikkens.com

Timber Pro Coatings.

Tel (503) 232-1705, 1-888-888-6095, Email [email protected] (Ben Harvey, Sales Mgr / Shari Stebar, Vice President).

Web Site http://www.timberprocoatings.com /

Substitution Requests: Submit for acceptance under provisions of Section 012500.

Indicate that manufacturer will conform to specified Qualifications, including requirement for manufacturer to employ and maintain full time architectural product representatives, technical field representatives, and testing equipment.

Product/Label Analysis: Submit indicating pigments and vehicles in percentages by weight and composition breakdown of pigments and vehicles in percentages by weight.

REGULATORY REQUIREMENTS

Conform to provisions of Section 014100.

PERFORMANCE CRITERIA

Single Source Responsibility: Supply primers, intermediate, and finish coats for each paint and coating system from a single manufacturer, except as otherwise specified.

Surface Preparation: Conform to MPI Architectural Painting Specifications Manual, SSPC, manufacturer’s instructions, and provisions of this Section for work as needed to prepare substrates to be free of conditions that may impair adhesion and uniformity.

Remove bond breakers, dust, foreign matter, and surface irregularities.

Prepare to prevent bleed-through of substrate material.

Paint System Application: Conform to MPI Architectural Painting Specifications Manual, and manufacturer’s instructions.

Paint Grade: Conform to Premium Grade, except as otherwise specified.

Minimum one primer coat and two finish coats, except as otherwise specified.

Additional coats as necessary to cover with no holidays or other surface imperfections.

Dry film thickness (DFT) and wet film thickness (WFT), as instructed by manufacturer.

MATERIALS

Painting and Coating Schedule: Refer to Schedule at end of this Section for products specified for specific finishes.

Surfaces Not Scheduled for Paints and Coatings: Where unscheduled surfaces are discovered following Bid, assume premium commercial quality paint or coating, meeting or exceeding Approved Product List, and as instructed by manufacturer’s technical representative. Submit to Architect for acceptance prior to beginning work.

Coatings: Ready mixed, except catalyzed coatings. Process pigments to consistency for uniform and homogeneous coatings, good flow and brushing qualities, drying or curing free of streaks and sags.

GLOSS AND SHEEN LEVELS

Conform to Gloss and Sheen Levels as tested in accordance with ASTM D523, regardless of that stated by manufacturer product data and shown on paint containers.

GLOSS AND SHEEN LEVELS GLOSS @ 60 DEGREES SHEEN @ 85 DEGREES
Gloss Level 1 Matt or Flat Maximum 5 Units Maximum 10 Units
Gloss Level 2 Low Sheen Maximum 10 Units 10 to 35 Units
Gloss Level 3 Eggshell 10 to 25 Units 10 to 35 Units
Gloss Level 4 Satin 20 to 35 Units Minimum 35 Units
Gloss Level 5 Semi-Gloss 35 to 70 Units (N/A)
Gloss Level 6 Gloss 70 to 85 Units (N/A)
Gloss Level 7 High Gloss More than 85 Units (N/A)

FINISHES AND COLORS

Field Painting Product Systems and Gloss Levels: As Schedules this Section.

[Paint and Stain Colors: Match paint colors at existing building from paint drawdown, as accepted by Architect.]

Paint and Stain Colors: Listing of paint manufacturer’s color does not constitute acceptance of paint manufacturer or product.


Following is an example.


(PNT-1): Benjamin Moore, 2005-20 Hot Apple Spice

(PNT-2): Sherwin-Williams, 6107 Nomadic Desert

(PNT-3): Sherwin-Williams, 6379 Jersey Cream

(PNT-4): Sherwin-Williams, 6680 Friendly Yellow

(PNT-5): Sherwin-Williams, 6046 Swing Brown

(PNT-6): Sherwin-Williams, 6094 Sensational Sand

(PNT-7): TBD (Gallery Hallway)

Gloss and Sheen Levels: As scheduled this Section[, and as follows for gypsum board finishes.

Painted Gypsum Board:

Ceilings: Flat or low sheen.

Walls: Eggshell.

Wet Areas (restrooms, janitorial, shower area): Semi-Gloss.

EXECUTION

EXAMINATION

Verify conditions ready to receive work of this Section before beginning work.

Arrange for adequate lighting, temporary heat, and ventilation.

Maximum Moisture Content of Substrates: Conform to manufacturer’s instructions and guidelines. Perform tests using commercial quality electronic moisture meter. Where exceeding following values, promptly notify Architect and obtain direction before beginning work.

Concrete: 17 percent. Cured minimum 28 days.

Concrete Slab-On-Grade: Perform calcium chloride test over 24 hour period or other test acceptable to manufacturer. Verify acceptable moisture emissions and pH levels.

Concrete Masonry: 17 percent

Exterior Wood: 19 percent.

Interior Wood: 15 percent.

Interior Finish Detail Woodwork, Including Trim, and Casework: 10 percent.

Plaster and Gypsum Materials: 17 percent.

MATERIALS TO BE FINISHED

Prepare and finish surfaces of materials, except as specifically excluded or otherwise specified.

Include Structural, Mechanical, and Electrical Items in rooms and spaces scheduled for painting. Paint out conduit and other such items to match color of adjacent surfaces.

Field paint exposed -to-view surfaces, whether or not indicated to receive coatings, except where specifically excluded by Contract Documents. Include:

Pre-finished items such as conduit, ductwork, hangers and seats;

Unfinished steel and wood surfaces.

Interior utility panels, grilles, and surfaces visible through vents and louvers.

MATERIALS NOT TO BE FINISHED

Refer to Finish Schedule for rooms or areas not required to be field painted.

Metals: Brass, bronze, copper, stainless steel, pre-finished metal, and plated metals other than galvanized metal, except as specifically indicated.

Plastic laminate, melamine, and other finished plastic surfacing.

Roofing, masonry, stone, and concrete, except as otherwise indicated.

Glass and clear plastic, except as otherwise indicated.

Substrates with specified factory-applied colored finishes and normally unfinished substrates:

Includes: Door hardware, electrical switch plates, fabrics, tackboards, porcelain enameled metal fabrications, and lighting fixtures.

Exception: Wire mold and other normally prefinished items mounted on surfaces receiving coatings: Paint out to match and blend with field surface.

Inaccessible materials permanently enclosed behind building construction and structural components.

SURFACE PREPARATION UNDER WORK OF OTHER SECTIONS

Field Substrate Preparation Specified Under Work of Related Sections: Crack free, finished, clean, and as needed to make substrates suitable for primers and finished coats specified for work of this Section, except minimal spot filling, spackling, and other preparation normally performed by work of this Section.

Shop Preparation and Primers for Metal Fabrications: Specified under work of Section 055000, except for spot priming and spot repair of shop primers prior to applying finish coats specified under this Section.

SURFACE PREPARATION PROCEDURES

Conform to:

MPI Architectural Painting Specification Manual, Surface Preparation.

SSPC- Surface Preparation Procedures.

Manufacturer instructions.

Contract Document provisions.

Mildew removal:

Do not use bleach to remove mold from carbon-based materials. These include paper, cellulous, wood, sucrose (sugar), gypsum board, and materials that are considered food for mold.

Contact Owner and Architect for remediation method for mold contamination of carbon-based materials.

Proceed with methods to remove stains as specified by for non-carbon based materials.

Concrete, [Portland Cement Plaster] and Concrete Unit Masonry Receiving Opaque Finish [Concrete Surfaces Receiving Translucent Stained Coatings]:

Allow 28 day curing period before beginning work.

Remove dirt, loose material, sand particles, loose mortar, scale, laitance, powder, stains, rust, oil, grease, efflorescence, grease, and other bond breakers.

Test plaster and masonry surfaces to verify cured and dry.

Point, fill, and repair minor cracks, holes, and other surface imperfections.

Steel and Iron: Put in condition to receive paint. Remove grease, rust, scale, dirt, and dust. Use prime paints compatible with finish coats. Conform to Section 099713 for exterior metal except as specified this Section.

Field Welded or Abraded Spots: Power tool, clean, and prepare, conforming to SSPC-SP-3. Spot prime by end of same day.

Surfaces Shop Primed Conforming to Section 055000: Solvent clean free of oil and grease before coating, conforming to SSPC-SP-1.

Surfaces Shop Primed with Alkyd Coatings and Coatings not Conforming to Section 055000:

Machine clean to SSPC SP-3.

Hand tool clean to SSPC SP-2 as required for removal of rust and scaling at difficult to reach locations.

Solvent clean free of oil and grease before coating, conforming to SSPC-SP-1.

Surfaces Not Previously Shop Primed:

Remove Rust and Scale: Power tool clean and prepare, conforming to SSPC-SP-3. Apply prime coat when thoroughly dry and before forming of visible rust.

Oil and Grease: Solvent clean, conforming to SSPC-SP-1, before applying finish coat.

New Pre-Primed and Prefinished Metals: Solvent clean in accordance with SSPC-SP-1.

Uncoated, Ungalvanized, and Existing Ferrous Metals: Power tool clean and prepare in accordance with SSPC-SP-3. Prime by end of same work day and before forming of visible rust.

Remove oil, grease, and other foreign substances by lacquer thinner, conforming to SSPC SPC-1.

Lightly scuff sand with 120 grit paper to break surface sheen without scratching or scaring surface.

Hot-Dipped Galvanized Steel Treatment: Conform to ASTM D6386 for preparation of galvanized surfaces prior to application of primers and other coatings directly to galvanized surfaces.

Newly Galvanized Steel:

Within 48 hours of galvanizing, and before zinc oxide or zinc hydroxide formations on surface, clean surfaces of oil and grease.

Smooth high spots and rough edges by sanding or sweep blasting.

Apply zinc-phosphate treatment or other acceptable adhesion promoter.

Partially weathered Galvanized Steel:

Test for and remove chromatic conversion coatings that may have been applied at factory.

Clean surfaces of oil and grease. Smooth high spots and rough edges by sanding or sweep blasting.

Remove wet storage stain using a mild ammonia solution, rinse with water, and air blow dry.

Apply paint coating within 30 minutes before zinc oxides begin to reform or apply zinc-phosphate treatment or other acceptable adhesion promoter.

Weathered Galvanized Steel:

After 1-1/2 to 2 years following formation of a hard zinc-carbonate surface, clean surfaces of oil, grease, and loose particles.

Smooth high spots and rough edges by sanding or sweep blasting.

Scuff and brighten using 3M metal finish pad to remove zinc oxidation.

Clean to remove surface contamination, conforming to 25, Etching Cleaner or SSPC-SP-1 Solvent Cleaning and Manufacturer's priming instructions.

Verify preparation with manufacturer.

Zinc Coat Galvanized Ferrous Metal for Dryfall Coatings and Dryfall Paint at Interior Overhead Ceilings:

Rust-Inhibitive, Low-Temperature Cure Dryfall Coatings: No preparation required over dust-free and dry surfaces.

Dryfall Paint (None Rust-Inhibitive): Conform to preparation surface preparation methods including solvent cleaning, test for chromate passivation, and etching cleaner.

[Clear-Coated Ferrous Metal: Clean to white metal, free of rust and stain , conforming to SSPC-SP-6, Commercial Blast Cleaning or SSPC-SP-10, Near White Blast Cleaning. Perform work under shop conditions and promptly apply clear coating before metal shows visible corrosion.]

Wood Products Receiving Opaque Finishes:

Clean to remove dirt, bond breakers, and material that is not suitable for paint adhesion to substrate.

Wipe off dust and minor grit prior to applying prime coat.

Fill nail holes and fine cracks after primer has dried.

Sand smooth and level with surface, ready for finish coat.

Maintain surface condition for subsequent finish coats.

Wood Products Receiving Transparent Finishes: Preparation: Sand, seal, and prepare surfaces to receive uniform coatings free of blotches, inconsistent absorption, irregular sheen, and color variations.

Remove stains, discolorations, marks, and other surface inconsistencies through sanding, bleaching, and other applicable methods.

Clean as for painted wood surfaces, prior to applying sanding sealer or basecoat.

Back Priming Wood:

Prior to installation, back prime concealed faces of panels, moldings, siding, and other thin wood, plywood, and panel material subject to warping and bowing.

Apply 2 coats of sealer, primer, or suitable finish system to balance finish on exposed face.

Gypsum Board, [Plaster,] [and] [Veneer Plaster] Surfaces:

Repair and remove minor irregularities, contaminations, dust, and dirt.

Where surface defects appear after prime coating, repair defects under work of appropriate Section, and reprime over repaired areas.

Do not begin surface preparation on gypsum board [, veneer plaster,] and other gypsum board materials that have been saturated by water. Notify Owner and Architect.

Mechanical and Electrical Work: Remove dirt, grease, and oil from metal and insulating coverings.

Surfaces Not Specified by MPI, SSPC, or manufacturer’s Instructions: Verify with Architect for surface preparation procedures.

RECOATING SURFACE PREPARATION


Applicable for renovation and re-coating of previous coatings.


Prepare existing coated substrates as needed to make suitable for work of this Section. Proceed as for new work following initial preparation conforming to - Architectural Painting Specification Manual, Surface Preparation, SSPC- Surface Preparation Procedures, manufacturer instructions, and Contract Document provisions.

Concrete and Masonry:

Remove old paint, chalking, laitance, and efflorescence down to bare substrate.

Fill holes and cracks with suitable filler.

For substrates not being recoated, match coloration of material being filled.

Metal:

Remove deteriorated painted surfaces.

Feather edges to prevent telegraphing of surface blemishes through painted surface.

Conform to this Section and Section 099713 for rust removal and spot repair primer.

Prime as necessary to prevent bleed-through of rust.

Wood, Prior to Recoating:

Remove and clean existing deteriorated painted surface down to sound substrate, suitable for new coatings.

Sand thick and sharp edges to make feather edge transitions needed to prevent telegraphing through finished paint surface.

Fill and patch checks, blemishes, and deteriorated surfaces.

Wood, Prior to Staining:

Proceed as for Recoated Wood, except strip down to bare wood free of coatings and foreign matter.

Spot repair to restore uniformity of color. Bleach stained and watermarked surfaces.

Lightly sand without changing uniform color and character of surface.

Gypsum Board, Veneer Plaster, and Gypsum Based Products:

Fill, sand, and spot prime.

Remove unsound coatings and bond breakers.

Apply bonding agent where patching compound overlaps existing painted surfaces.

Sand and feather edge transitions to eliminate photographing through finished paint surface.

Remove excessive paint build-up to make sharp corners and edges.

PROTECTION

Take measures to protect surfaces not receiving work of this Section including protection from overspray, adjacent surfaces and down wind surfaces.

Provide drop cloths, shields, and protective equipment.

Repair or replace damaged surfaces caused by failure to provide suitable protection.

Remove or mask electrical outlets and switch plates, mechanical diffusers, escutcheons, registers, surface hardware, fittings, fastenings, and other items not receiving coating system.

Correct minor defects and clean substrate surfaces included under work of this Section.

Remove coatings that exhibit surface defects or unsuitable surface adhesion.

APPLICATION

Conform to manufacturer's instructions, - Architectural Painting Specification Manual, and provisions of Contract Documents.

Conform to Premium Grade, including application of two finish coats over prepared and primed substrates.

Apply as many additional coats for complete coverage and for acceptable finished appearance, free of holidays and color irregularities.

Back-roll, back-brush, and perform other work as necessary to lay down gypsum board fuzz, push spray-applied coatings into surfaces, and to even out and make for smooth, uniform coated surfaces.

Apply primer and each finish coat in slightly different hue as means to verify multiple coat coverage.

Conform to manufacturer’s instructions for wet film and dry film thickness of coatings.

Verify wet film thickness (WFT) by use of wet film gage during application.

Test dry film thickness (DFT) using Tooke or other accepted measuring device.

PATCHING

Repair surfaces damaged during construction activities. Spot repair and refinish as necessary for finished appearance prior to Substantial Completion and Owner occupancy.

REPLACEMENT OF HARDWARE AND MISCELLANEOUS ITEMS

Reinstall items previously removed for painting, including hardware, electrical plates.

FIELD QUALITY CONTROL

Independent Field Inspection and Testing: Conform to Quality Assurance provisions specified this Section, [and provisions of Section 014324 for Painting Inspection Services].

Manufacturers Field Services: Conduct field services by manufacturer’s local senior technical field representative.

Attend Pre-Construction Conference, view mockups, make intermittent site visits, make final site visit at project completion.

Verify conformance to manufacturer’s instructions and provisions of Contract Documents for products and procedures.

Provide technical assistance to help achieve high quality results.

Verify mil thickness with wet film gauge, in selected locations.

Test surfaces with Tooke or approved dry film gauge, for total DFT in selected areas.

Promptly notify Architect of suspected non-conforming work and other irregularities.

ADJUSTING

Take measures as necessary and as directed by Architect to repair, prepare, and recoat systems not conforming to Contract Document provisions.

CLEANING

As Work proceeds, promptly remove spilled, and splattered paint and coating products so as not to damage surfaces.

Maintain premises free from unnecessary accumulation of tools, equipment, surplus materials, and debris.

At conclusion of work, thoroughly clean paint and coatings from surfaces not designated to be painted.

Do not scratch or damage surfaces.

Verify chemical compatibility of cleaners to materials to be cleaned.

Leave premises neat and clean; free from debris and residue from work of this Section.

Do not dump paint, stains, chemicals and clean/wash painting equipment anywhere in the landscaping around the building, site, or property, including the adjoining property.

CONCRETE UNIT MASONRY BLOCK FILLERS

Interior/Exterior Latex Block Filler - Concrete Unit Masonry and Concrete (as necessary to reduce pinholes): http://www.specifypaint.com/APL/paintinfo_APL/MpiNumber.asp?ID=4000

Benjamin Moore, Super Spec Latex Block Filler, 206.

Coronado Paint, Super Kote 5000 Latex Block Filler, 958-11.

PPG Architectural Coatings, Speed Hide Int /Ext Block Filler 6-7 or Glidden Professional, Prep N Prime Block Filler, 3010.

Kelly-Moore, Fill & Prime Acrylic Block Filler, 521.

Miller Paint Company, Acrylic Block Filler, 6015.

Rodda Paint, Sprayable Smooth Block Filler, 501901.

Sherwin-Williams, PrepRite Interior/Exterior Block Filler, B25W00025 (45 g/L VOC).

Tnemec, Epoxo Block WB, Inorganic Hybrid Water-Based Epoxy, 1254 (zero VOC).


Schedule default specifies Best Commercial Grade products. Premium Grade products are listed for some products. These generally may cost 20 - 30 percent more than Best Commercial Grade and should only be specified under special conditions. Where Premium Grade is under consideration, evaluate products based on a Label Analysis of vehicles and pigments. In listings where paint companies do not have premium paints or supply the same paint for premium as for commercial, it is unfair to specify premium against these products.

VERIFY SELECTED MANUFACTURERS AND PRODUCTS WITH EACH PROJECT. THESE ARE CONSTANTLY CHANGING.


EXTERIOR FIELD PRIMERS SCHEDULE

[Shop Primed and Galvanized Exterior Metal: Conform to provisions of Section 055000 for primers and treatments for field-applied coating systems.]


Following is applicable where Section 099713 – Steel Coatings is used.


[Primers and Coatings for Exterior Ferrous Metal and Ferrous Metal Subject to Moisture Exposure: Refer to Section 099713 for Steel Coatings.

Includes shop primed and galvanized ferrous metal.

Includes structural, mechanical, and electrical work, whether prefinished or not, except where specifically excluded.]


Acrylic finish coat system for exterior metal may also be specified by. Section 099713 for steel coatings.


Exterior Shop Primed and Galvanized Ferrous Metal: Include interior and exterior surfaces of doors and frames at exterior walls, [handrails], and other galvanized metal surfaces.

Pre-Treatment, Preparation, and Shop Primers for Ferrous Metals and Aluminum: As specified under work of Section 055000 and pre-primed metal under work of related Sections.

Pre-Treatment for Steel Doors and Frames: As specified Section 081113.

Field Applied Etching Cleaner: Etching Cleaner. Use in lieu of SP-1 Solvent Cleaning, specified under preparation. http://www.specifypaint.com/APL/paintinfo_APL/MpiNumber.asp?ID=25000

Diamond Vogel, Great Lakes Laboratories, Clean 'n Etch.

Kelly Moore, Jasco, Metal Etch, 0700-0703

PPG Architectural Coatings, Prep 88 Heavy Duty Cleaner Concentrate

Rodda / Cloverdale, Henkel Amchem Galvaprep / ClovaClean, 78100.

Sherwin-Williams, Sherwin-Williams, Clean & Etch.

Columbia Paint/Spectra-Tone CGI, Jasco, Metal Etch, 0700-0703.

Exterior Water Based Rust-Inhibitive Metal Primer for Cleaned/Etched Galvanized Ferrous Metal and As Spot repair for Shop Primed Surfaces: Do not apply alkyd primers or coatings directly to galvanized surfaces. http://www.specifypaint.com/APL/paintinfo_APL/MpiNumber.asp?ID=134000

Benjamin Moore, SuperSpec HP Acrylic Metal Primer, P04

Coronado Paint, Rust Scat Acrylic Metal Primer, 36-11.

Kelly Moore, Acry-Shield 100% Acrylic Metal Primer, 1725.

Miller, Acrimetal DTM Primer/Finish, 5000.

PPG Architectural Coatings, Speedhide 6-209 Ferrous Metal Galvanized Steel Primer or PPG 90-912 Pitt Tech Plus

Rodda, Barrier III High Solids Primer, 708225 [Multi Master Primer, 50890].

Sherwin-Williams, DTM Acrylic Primer/Finish, B66W1.

Tnemec, Uni-Bond, Self-Crosslinking Acrylic, Corrosion-Resistant Primer Series 115.

Exterior Primer - Factory Pre-Coated Aluminum for Acrylic Paint Finish: Verify with manufacturer for primers with alkyd and fluoropolymer coating systems. http://www.specifypaint.com/APL/paintinfo_APL/MpiNumber.asp?ID=17000

Benjamin Moore, Super Spec HP Acrylic Metal Primer, P04.

Coronado Paint, Rust Scat Acrylic Metal Primer 36-11

Kelly-Moore, Acry-Shield 100% Acrylic Metal Primer, 1725.

Miller, Acrimetal Primer/Finish, 5000.

PPG Architectural Coatings, PPG 90-912 Pitt Tech Plus.

Rodda, Multi Master DTM Metal Primer 508901.

Sherwin-Williams, DTM Primer/Finish B66.

Tnemec, Uni-Bond, Self-Crosslinking Acrylic, Corrosion-Resistant Primer Series 115.

Exterior Acrylic Primer - Cementitious Materials, Including Concrete, Concrete Unit Masonry, and Cementitious (Fiber-Cement) Panels: http://www.specifypaint.com/APL/paintinfo_APL/MpiNumber.asp?ID=3000

Pre-Primed Fiber-Cement: Refer to Section 074646.

Concrete Masonry Block Fillers: As specified by this Section.

Field Primers:

Benjamin Moore, Moore’s Acrylic Masonry Sealer, 066 Moore’s

Coronado Paint, Supreme Waterborne Acrylic Bonding Sealer, 8-11.

Kelly-Moore, Acry-Shield 100% Acrylic Masonry Primer, 247.

Miller, Kril Primer Sealer, 6040.

PPG Architectural Coatings, Perma – Crete Concrete and Stucco Primer 4-503

Rodda, Surfbond II Masonry Conditioner, 501801. [First Coat Primer, 501601

Sherwin-Williams, Loxon Acrylic Primer, A24w300.

Tnemec, Elasto-Grip FC Low Temperature Waterborne Modified Polyamine Epoxy, Series 151-1051.

Exterior Acrylic-Latex Primer for Gypsum and Gypsum Plaster Soffits.

Benjamin Moore, SuperSpec Latex Exterior Primer 169.

Coronado, Supreme Waterborne Acrylic Bonding Sealer 8-11.

Kelly-Moore, Color Shield Exterior Acrylic Primer-Sealer 250.

Miller, Kril Primer Sealer, 6040.

PPG Architectural Coatings, Seal Grip Acrylic Universal Primer 17-921,

Rodda, Multi Prime, 505901.

Sherwin-Williams, Preprite Problock Latex Primer B51W20.

Exterior Primer - Wood Siding and Trim for Paint Finish:

Acrylic Wood Primer : http://www.specifypaint.com/APL/paintinfo_APL/MpiNumber.asp?ID=6000

Benjamin Moore, Moorcraft, Super Spec Exterior Latex Primer 169

Coronado Paint, Supreme Oil House Paint Primer, 5-11[Supreme Waterborne Acrylic Bonding Sealer 8-11]..

Kelly Moore, Acry-Shield 100% Acrylic Exterior Wood Primer 255.

Miller Paint Company, Miller Prime, 6060.

PPG Architectural Coatings, Speed Hide Ext. Acrylic Wood Primer 6-609.

Rodda / Cloverdale, First Coat Exterior/Interior Latex Primer 501601.

Sherwin-Williams, A-100 Exterior Latex Wood Primer B42W8041 [Exterior Latex Wood Primer B42 Series<premium>].


Verify following.


Exterior Plastic (Including PVC) - Bonding Primer:

Benjamin Moore, Fresh Start, All-Purpose Acrylic latex Primer 023.

Coronado Paint, Grip & Seal Acrylic Latex Primer 116-11

Kelly Moore, Uni-Prime All Purpose Primer-Sealer-Stain Killer 295 [Litho Industrial Label Martin Mathys Pegalink Acrylic Adhesion Promoting Primer 202600].

Miller Paint Company, Zinsser All Prime Acrylic Primer.

PPG Architectural Coatings, Seal Grip Acrylic Universal Primer 17-921.

Rodda / Cloverdale, XIM UMA modified acrylic bonding water based primer.

Sherwin-Williams, PrepRite Bonding Primer B51W50.

Tnemec, Uni-Bond DF, Series 115.

EXTERIOR PAINT FINISH COATINGS

Exterior Shop Primed Metal: Include interior and exterior surfaces of doors and frames at exterior walls, and other galvanized metal surfaces.

Acrylic coating systems may be too soft for handrails and surfaces subject to oils from hands. This may be more suitable for painting walls and trim. Verify application temperatures for products suitable for application ambient and surface temperatures suitable for 35 degrees F and above. Most are not suitable below 50 degrees F

Two-Coat, Acrylic Semi-Gloss Finish - Gloss Level 5:

Benjamin Moore, Super Spec HP Acrylic Semi-Gloss, P29 [Gloss Finish: DTM Acrylic Latex P-28]

Coronado Paint, Crylicote Gold Acrylic Semi-Gloss House & Trim Paint 2 Line.

Kelly-Moore, Dura-Poxy 100% Acrylic Semi-Gloss Enamel 1685.

Miller Paint Company, Acrimetal DTM, 5200 Semi-Gloss.

PPG Architectural Coatings, Pitt Tech Plus Int/Ext Semi-Gloss DTM 90-1210 .

Rodda Paint, Multi Master W.B. DTM Enamel, Semi-Gloss 548901.

Sherwin-Williams, Exterior Latex A82 Semi-Gloss, A-100 [Duration Ext Gloss K34 Series]

Tnemec, Enduratone, Water-based, Low VOC, high dispersion, pure acrylic coating Semi-Gloss, Series 1029.


Specify following for higher quality coating systems for exterior primed steel for low temperature conditions of 35 degrees F up to 120 degrees F. Specify here or specify product in Section 099713 - Steel Coatings.


Exterior Shop Primed Metal: Include interior and exterior surfaces of doors and frames at exterior walls, [handrails], and other galvanized metal surfaces. High performance, 35 degree F low temperature, high performance acrylic, low VOC, high solids resin.

Two-Coat, Acrylic Semi-Gloss Finish - Gloss Level 5:

Benjamin Moore,

Coronado Paint,

Kelly-Moore,

Miller Paint, Acrimetal DTM, 5200 Semi-gloss.

PPG Architectural Coatings.

PPG -Speed Hide 6-900,100% Acrylic Semi-Gloss.

PPG Manor Hall 70-101, 100% Acrylic or Glidden Professional.

Rodda,

Sherwin-Williams, Resilience, Exterior Latex Satin K43 Series.

Tnemec,

Enduratone, Water-based, Low VOC, high dispersion, pure acrylic coating Semi-Gloss, Series 1029


Open web steel joists with manufacturer’s SSPC 15 paint coating should be machine wire brush cleaned to remove loose rust and un-adhered coating and material and new primer applied. New primer should be an alkyd-based product to prevent saponificaton between coatings<?> Finish coat should also preferably be an alkyd.

Saponificaton: the reaction of a metallic alkali (base)) with a fat or oil to form soap. Thus the issue with using alkyd /oil primers on zinc /metallic/ galvanized materials.


Open Web Steel Joists and Other Steel Fabrications Shop Primed with Alkyd Coatings and Other Coatings not Compatible with Waterborne Coatings specified by this Section.

Field Preparation: Clean as specified by this Section.

Surface Tolerant Primer: Tnemec, Omnithane, Series 530-1201, Moisture-Cured Aromatic Urethane. Color: Aluminum.

Finish Coat: Tnemec, Uni-Bond, Series 115 DF, Modified Acrylic.

Exterior Finish Coats for Concrete, Masonry, [Wood] and Cementitious (Fiber-Cement) Panels.

Two-Coat Acrylic - Flat Finish (Gloss Level1): [<Consider using eggshell for exterior siding for better dirt control >] http://www.specifypaint.com/APL/paintinfo_APL/MpiNumber.asp?ID=10000

Benjamin Moore, Ultra Spec EXT Flat Finish N447.

Coronado Paint, Supreme Acrylic Flat House Paint 8 Line.

Kelly Moore, Color Shield Exterior 100% Acrylic Flat 1200.

Miller Paint Company, Acri Lite Exterior Acrylic 6900.

PPG Architectural Coatings, Speed Hide Exterior Flat 6-601 Series.

Rodda Paint, AC-910 Exterior Acrylic Latex Flat 511901.

Sherwin Williams, A-100 Exterior Latex Flat A6 Series.

Exterior Two-Coat Acrylic Low Luster/Eggshell Finish (Gloss Level 2): http://www.specifypaint.com/APL/paintinfo_APL/MpiNumber.asp?ID=214000

Benjamin Moore, Low Gloss Metal and Wood Enamel 363

Coronado Paint, Crylicote 100% Acrylic Satin House Paint 410 Line.

Kelly Moore, Color Shield 100% Acrylic Exterior Low Sheen 1210.

Miller Paint, Acri Lite Exterior Acrylic 7000.

PPG Architectural Coatings, Speedhide 100% Acrylic Satin 6-2045 Series.

Rodda Paint, AC909 Acrylic Latex Satin, 521101.

Sherwin-Williams, A-100 Satin, A82 Series.

Two-Coat Acrylic Satin Finish (Gloss Level 3-4) : Exterior Latex, Low Sheen, MPI Gloss Level 3 to 4<verify this selection - satin is not included in PNW painters cross-reference chart.>

Benjamin Moore, Ultra Spec EXT Satin Finish N448.

Coronado Paint, Crylicote 100% Acrylic 0 Line

Kelly Moore, Color Shield 100% Acrylic Exterior Low Sheen 1210.

Miller Paint Company, Acri-Lite Acrylic Satin 7400.

PPG Architectural Coatings, Speed Hide Exterior Satin 6-2045 Series.

Rodda Paint, Unique II, Low Gloss Ext./Int. Latex Enamel, 532001 [Ultimate Exterior Satin. 522501x.]

Sherwin-Williams, A-100 Satin Latex A82 Series 1.3 DFT.

Two-Coat Acrylic - Semi-Gloss Finish (Gloss Level 5): http://www.specifypaint.com/APL/paintinfo_APL/MpiNumber.asp?ID=11000

Benjamin Moore, Super Spec HP Acrylic Semi-Gloss P29.

Coronado Paint, Crylicote Gold Acrylic Semi-Gloss House & Trim Paint 2 Line.

Kelly Moore, Color Shield Exterior Acrylic Semi-Gloss Paint 1215.

Miller Paint Company, Acri-Lite Acrylic, 7500 Semi-Gloss.

PPG Architectural Coatings, Speed Hide Exterior Semi-Gloss 6-900 Series.

Rodda Paint, Unique II Semi-Gloss Exterior Latex Enamel, 542001.

Sherwin Williams, A-100, Exterior Gloss Latex A8W16.

Tnemec, Endura-Shield, Waterborne Acrylic Polyurethane, Semi-Gloss Series 1029.


Proprietary to Tnemec. Breaths and is somewhat elastomeric. Falls under category of being a special coating. Too soft for flooring. Consider other paint products to be more inclusive.


Exterior Elastomeric - Flat Finish Coating for Portland Cement Plaster and Gypsum Soffit Sheathing:

Tnemec: <minimum 40 degrees F>

One Coat: Tnemec, Series 151 Elasto-Grip FC, Waterborne Modified Polyamine Epoxy.

Two-Coats: Tnemec, Series 156 Enviro-Crete, Modified Waterborne Acrylate, Smooth Finish

[PPG Architectural Coatings: <minimum 50 degrees F>

One Coat: PPG Perma Crete 4-603 Alkali Resistant Primer or GliddenProfessional 6001 Hydrosealer Waterborne Primer Sealer

Two-Coats: PPG Perma Crete Pitt-Flex elastomeric 4-110 or GliddenProfessional Decra – Flex 2260 Smooth, Elastomeric Waterborne Coating]

[Rodda Paint: <minimum 50 degrees F>

One Coat: Rodda Paint, pHlextite Elastomeric Primer / Finish, 512301, 6.6-8.5 mils DFT.

Two-Coats: Rodda Paint, Super Roflex Elastomeric 511301 7.5-8.5 mils DFT.


OR - Verify - following is not updated and includes primers and topcoats. Following require minimum 50 degree F ambient and surface temperature except Tnemec below which is OK at 40 degrees F and above.


Exterior Elastomeric - Flat Finish Coating for Portland Cement Plaster and Gypsum Soffit Sheathing: http://www.specifypaint.com/APL/paintinfo_APL/MpiNumber.asp?ID=113000

Benjamin Moore

One Coat: Acrylic Masonry Sealer (066), 1 mil DFT

Two-Coats: Moorlastic 055 Acrylic Elastomeric Finish, 8.8 mils DFT per coat.

Coronado Paint,

One Coat: Elastite, 100% Acrylic Masonry Sealer 48-11

Two-Coats: Elastite, 20 mil Acrylic Elastomeric Coating 162-1

Kelly-Moore:

One Coat: Acry-Shield 100% Acrylic Masonry Primer 247.

Two-Coats: Kel-Seal Acrylic Terpolymer Coating 1128.

Miller Paint Company:

One Coat: Miller Kril Primer 6040.

Two-Coats (12 – 15 mils total dft): Miller Milastic Elastomeric 8800.

PPG Architectural Coatings, Glidden Professional:

One Coat: PPG Perma Crete 4-603 Alakli Resistant Primer or GliddenProfessional 3210 Gripper Multi-Purpose Primer Sealer or 6001 Hydrosealer Waterborne Primer Sealer

Two-Coats: PPG Perma Crete Pitt-Flex elastomeric 4-110 or GliddenProfessional Decra-Flex, Elastomeric Coating 2260 Smooth.

Rodda: 10 year application and material Warranty.

One Coat: Rodda, Surf-Bond II, Acrylic Emulsion Coating, adhesion promoter, 1 mil DFT.

Two-Coats: Rodda, Super Roflex Elastomeric Coating, 7.5 to 8 mils DFT each coat.

Sherwin Williams:

One Coat: Loxon Acrylic Primer A24.

Two-Coats: Sherlastic A5W151.

Tnemec:

One Coat: Tnemec, Elasto-Grip FC, Waterborne Modified Polyamine Epoxy Series 151.

Two-Coats: Tnemec, Enviro-Crete, Modified Waterborne Acrylate, Smooth Finish Series 156.

Exterior Asphalt and Concrete - Traffic Marking and Game Lines: Water based latex type pigmented coating for interior and exterior. White or Yellow as selected by Architect.http://www.specifypaint.com/APL/paintinfo_APL/MpiNumber.asp?ID=97000

Benjamin Moore, Safety & Zone Marking Latex, P58. <P designations conform to AIM ruling for VOC content.

Coronado Paint, Super Kote 5000 Acrylic Traffic Marking Paint 66 Line.

Kelly-Moore, Zone Marking Paint Lead Free Waterborne 1472.

Miller, Kelly-Moore, Zone Marking Paint Lead Free Waterborne, 1472.

PPG Architectural Coatings, Zoneline Traffic Paint 11-53.

Rodda, Professional Maintenance, Driveline - White/Yellow 7341/2.

Sherwin-Williams, Setfast Acrylic Waterborne Traffic Marking Paint TM225/TM226.

EXTERIOR STAINED FINISHES


Stained concrete finish may be specified by this Section or a separate Section. Chemprobe may also be of such high VOC content that it can no longer be used. Verify


Exterior Vertical Concrete - Opaque Stained Finish: Solvent Based Acrylic with Color Flattening Fumed Silica and Non-fading Inorganic Oxide Pigments.

Two-Coat Finish: Chemprobe Technologies, Conformal Stain WB at 200 sf per gallon, and as instructed by manufacturer.

Two Coat Finish: United Coatings, Canyon Tone Stain as distributed by Miller Paint.

Exterior Vertical Concrete - Tinted Stained Finish: Waterborne, alkaline-resistant, containing crystalline silica for concrete. Two to three coat finish.

Coronado. Final Finish WB Tilt Up Concrete Stain 1054 Line

Sherwin-Williams, Series A31, Vertical Concrete Stain 107.32.

Kelly-Moore, Rust-Oleum, Semi Transparent Concrete Stain

PPG – Perma Crete Color Seal WB Int/Ext Concrete Stain

Exterior Vertical Concrete - Translucent Stained Finish: Solvent Based Acrylic with Color Flattening Fumed Silica and Non-fading Inorganic Oxide Pigments.

Two-Coat Finish: Chemprobe Technologies, Conformal Stain WB.

One Coat: Apply Conformal Clear at 150 foot per gallon.

Two-Coats: Apply one part Conformal Stain WB to 9 parts water at 150 foot per gallon


Environmentally compliant, low VOC.


Exterior Heavy Timber and Glued-Laminated Construction: Clear, Transparent UV Resistant Natural Oil Wood Finish.

Two-Coat Application: Timber Pro Coatings, Timber Pro UV.

[Kelly-Moore, Cabot 9200 Clear Solution]

Miller Paint, Storm System Category 1 Natural Oil Finish.

PPG Sun Proof Tinted Waterproofing Sealant Alkyd Oil Toner 77-1971


OR – Following products require evaluation. They are probably not equivalent in performance.


Exterior Glulam Beams and Wood Soffits –Transparent, Natural Finish:

Benjamin Moore:

Two Coats: Benjamin Moore Arborcoat Transparent Stain Natural 637(10)

One Coat: Benjamin Moore Arborcoat Clear Coat 636

Miller Paint, Storm System Category 2 Toned & Semi-transparent Stain.

Sikkens

Sikkens Cetol 1, Exterior Wood Oil/Alkyd Formulation, 078 - Natural.

Two-Coats Sikkens Cetol 23 Plus, Advanced Alkyd resin with UV Inhibitors, Satin Sheen, 078 - Natural.

Sherwin Williams:

One Coat: DeckScapes Ext. Waterborne Toner Stain, A15T452.

One Coat: DeckScapes Ext. Waterborne Clear, A15T260.


OR - This may not be a satisfactory coating for exterior based on longevity and maintenance.


Exterior Glue-Lam Units - Satin Spar Marine Varnish:

Two-Coat Application, Sand lightly between coats.

Benjamin Moore, Moore's, Sunbar Clear Spar Varnish 441

Coronado Paint, Marine Spar Varnish 149-100

Kelly Moore, Varathane Premium Exterior Spar Urethane.

Miller Paint Company, Ultraviolet Shield Spar Varnish 1209.

PPG Architectural Coatings, Olympic Int / Ext Spar Varnish 41844 Clear Gloss 41846 Clear Satin

Rodda Paint, McCloskey, Man O'War Spar Varnish - Satin.

Sherwin Williams, Minwax, Helmsmann, Spar Varnish.

Exterior Wood - Stained Finish: Includes wood siding, soffits, glue-lams, and wood indicated to be stained. http://www.specifypaint.com/APL/paintinfo_APL/MpiNumber.asp?ID=13000http://www.specifypaint.com/APL/paintinfo_APL/MpiNumber.asp?ID=16000< Verify waterborne and solvent entries >

[Primer: As instructed by manufacturer to reduce tannin migration.]

Two-Coats: [Solid body Acrylic or Latex-Acrylic Waterborne Stain.]

Benjamin Moore, Benjamin Moore, Acrylic Latex Solid Siding Stain, N089 [Alkyd Semi-Transparent Deck and Siding Stain 328] [ Moorcraft Super Spec Acrylic Exterior Stain 179).] [Semi-Solid Deck& Siding Stain 329].

Coronado Paint, [Maxum 100% Acrylic Solid Color Stain M2000 Series]

Kelly-Moore, Storm System Category 3 Semi-solid, Category 4 Solid Color Stain as distributed by Miller Paint.

PPG Architectural Coatings, SunProof Solid Alkyd 77-1310 / Acrylic 77-1110 Deck, Fence and Siding Stain or Flood SWF-Solid Color Wood Finish, 15 year siding, 5 year deck guaranteed.

Rodda, Rural Manor Stain 71410XX / Terra 511002 x, Solid Body Vinyl Acrylic, / Acrylic Emulsion Stain Coating.

Rodda / Cloverdale Paint, Timberlox Acrylic Solid Hide Stain, 06803 [Waterborne Exterior Semi-Transparent Stain 06803].

Sherwin-Williams, WoodScapes Solid Color Acrylic Exterior House Stain A15 Series.

Exterior Wood - Bleaching Oil Finish:

Allow pressure treated wood 6 months weather exposure before coating, except as otherwise instructed by manufacturer.

Two-Coat Application: Samuel Cabot Co., Cabot, Bleaching Oil No. 0241.

Exterior Penetrating Wood Sealer and Transparent Finish: < Verify >

Application: One coat at 150 to 200 foot per gallon. Additional coats as necessary for complete penetration and to bead water:

[Benjamin Moore, Hardwood Finish 321]

Kelly-Moore, Storm System Category 1 Natural Oil Finish, as distributed by Miller Paint.

PPG Architectural Coatings, Flood CWF-UV (4 yr siding, 2 year deck guaranteed) or CWF-UV5 (5 yr siding, 3 yr deck guaranteed).

Sherwin-Williams, DeckScapes< Formerly Cuprenol >, Clear Deck & Siding Wood Finish, VOC compliant (79 grams per liter), UV inhibitors, penetrating water based water repellant.

INTERIOR PRIMERS

Interior Ferrous Metal Primer:

Acrylic or Alkyd Rust Inhibitive Metal Primer: Apply as shop primer coats under work of Section 055000 and as spot repair / field primer under work of this Section:

Benjamin Moore, Super Spec HP Acrylic Metal Primer, P04.

Coronado Paint, Coronado Rust Scat Acrylic Metal Primer 36-11

Kelly-Moore, Acry-Shield 100% Acrylic Metal Primer, 1725 or Kel Guard Rust Preventative Alkyd Primer 1711.

Miller Paint Company, Acrimetal DTM Primer/Finish, 5000.

PPG Architectural Coatings, Pitttech Plus Int / Ext DTM Industrial Primer 90-912

Rodda, Metal Master W/B Metal Primer 508901.

Sherwin-Williams, Pro Industrial Pro -Cryl Universal Primer B66W00310 (99 g/L VOC).

Interior Concrete [and] Concrete Masonry [and] [Cementitious Plaster Primer]:

Masonry Block Fillers:

Benjamin Moore, Super Spec Latex Block Filler 206.

Coronado Paint, Super Kote 5000 Latex Block Filler, 958-11.

Kelly-Moore, Fill & Prime Acrylic Block Filler 521.

Miller Paint Company, Acrylic Block Filler 6015.

PPG Architectural Coatings, PPG Speed Hide Int/ Ext Block Filler 6-7.

Rodda Paint, Sprayable Smooth Block Filler 501901.

Sherwin-Williams, PrepRite Interior/Exterior Block Filler B25W00025 (45 g/L VOC).

Tnemec, Epoxo Block WB, Inorganic Hybrid Water-Based Epoxy 1254 (zero VOC).

Alkali-Resistant Primer:

Benjamin Moore, Super Hide Primer Undercoater 284.

Coronado Paint, Super Kote 3000First Coat Primer 958-11.

Kelly-Moore, Acry-Shield 100% Acrylic Masonry Primer 247.

Miller Paint Company, Kril Primer Sealer, 6040.

PPG Architectural Coatings, PPG Int / Ext Alkali Resistant Primer 4-603.

Rodda, pHlex-tite Acrylic Elastomeric Primer 512301 or Surfbond II, 501801.

Sherwin-Williams, Loxon Concrete & Masonry Primer, A24W8300 (96 g/L VOC).

Interior Gypsum Board, Gypsum Plaster, and Veneer Plaster Primer:

Acrylic Primer/Sealer:

Benjamin Moore, Super Hide Primer Undercoater, 284.

Coronado Paint, Super Kote 3000 First Coat Primer, 958-11.

Kelly-Moore, Pre-Cote Wallboard & Masonry Primer Sealer, 95-100.

Miller Paint Company, Premium PVA, 6020.

PPG Architectural Coatings, Speed Hide Interior Latex Sealer QD 6-2.

Rodda, Roseal Wall Board Sealer 507701.

Sherwin Williams, Contractor Primer, B28WF162 (86 g/L VOC).


Verify following - this can probably be deleted. Verify with manufacturers. Is this a PVA primer?


Interior Gypsum Board - Walls to Receive Wall Coverings:

One Coat: Waterborne Primer/Sealer, Vapor Barrier, perm rating less than 1.0.

Benjamin Moore, Super Spec Vapor Barrier Primer 260

Coronado Paint, N/A

Kelly-Moore, Vapor-Shield Wallboard & Masonry Primer/Sealer, 95-500

Miller Paint Company, Vapor-Lok Moisture Vapor Barrier 1545.

PPG Architectural Coatings, PPG Seal Grip Perm Sealer VBP 17-9801.

Rodda Paint, Vapor Block 507901.

Sherwin-Williams, Vapor Barrier B72W00001.

Interior Wood Primer:

Primer for Acrylic Enamel and Alkyd Enamel Finishes:

Benjamin Moore, Super Hide Primer Undercoater, 284.

Coronado Paint, Super Kote 5000 Acrylic Enamel Undercoater, 78-11.

Kelly-Moore, Water-Oil Hybrid Primer / Undercoater, KM 265.

Miller Paint Company, Acrylic Enamel Undercoat, 2840.

PPG Architectural Coatings, Seal Grip Primeline FD Latex Wood Primer 17-951.

Rodda, Unique II Enamel Undercoater, 502001.

Sherwin-Williams, PrepRite Multi-Purpose Latex Primer, B51W8020 (96 g/L VOC).

Interior Epoxy Primer:

Primer: Two-Component Waterborne Epoxy Primer for Semi-Gloss or Gloss Finish (Gloss Level 5-6):

Benjamin Moore, Super Spec Acrylic Epoxy Coating 256

Coronado Paint, N/A

Kelly-Moore, Envira-Poxy Water Reducible Epoxy Primer 7125.

Miller, 4200/4440 Waterborne Epoxy Semi-Gloss or Gloss.

PPG Architectural Coatings, Pitt Glaze WB Acrylic Epoxy 16-551 Series.

Rodda / Cloverdale, EcoLogic Waterborne Epoxy, 70503 Gloss / 70504 Semi-gloss.

Sherwin-Williams, [__].

INTERIOR PAINTING AND COATING SCHEDULE

Conform to manufacturer's instructions and provisions of Contract Documents.

Interior Clear Coated Ferrous Metal: Refer to for spot repair of steel stairs and handrails specified under by Section 055000.


Verify paint coatings over metal with manufacturers. Items in dark red are probably a better an option for durability on metal and are from earlier master specifications. Black colored text conforms to that shown on the PNW Paint Reps consensus painting cross-reference document. Review with manufacturer for surface substrate and project requirements.


Interior Metal - Paint Finish:

Shop Primer Coat: Refer to This Section and Section 055000 for metal shop fabrications.

Spot repair / Field Primer: As specified by this Section. http://www.specifypaint.com/APL/paintinfo_APL/MpiNumber.asp?ID=107000

Two-Coat, Acrylic Eggshell Finish (Gloss Level 3): 151 Light Industrial Coating, Interior, Water Based (MPI Gloss Level 3). http://www.specifypaint.com/APL/paintinfo_APL/MpiNumber.asp?ID=151000

Benjamin Moore, [Super Hide Latex Eggshell 286] [Ultra Spec 500 Interior Eggshell N538].

Coronado Paint, Super Kote Latex Eggshell Enamel 5000.

Kelly-Moore, [Professional Interior Acrylic Eggshell Enamel 1010] [Dura-Poxy Plus Acrylic Eggshell Enamel 1686]

Miller Paint, [Premium, 3880] [Acrimetal DTM Velvet 5000].

PPG Architectural Coatings, Speedhide Pro EV 12-310 Series, Speedhide 6-411 Series.

Rodda, Master Painter Satin, 523101.

Sherwin-Williams, [ProMar 400 Latex Eg-Shel B20WF351] [ProMar 200 Latex Eggshell B20W200].

Two-Coat, Acrylic Semi-Gloss Finish (Gloss Level 5): http://www.specifypaint.com/APL/paintinfo_APL/MpiNumber.asp?ID=153000

Benjamin Moore, [Super Hide Latex Semi-Gloss Enamel 283] [Super Spec HP DTM Acrylic Latex, P29].

Coronado Paint, [Super Kote 5000 Acrylic Semi-Gloss Enamel 32Line] [Corotech DTM Acrylic Semi-Gloss 182 Line].

Kelly-Moore, [Professional Interior Acrylic Semi-Gloss Enamel 1050] [Dura-Poxy+ Semi-Gloss Acrylic Enamel, 1685].

Miller Paint, [Premium, 4580] [Acrimetal Int/Ext Latex Semi-Gloss Primer/Finish, 5200].

PPG Architectural Coatings, Speedhide Pro EV 12-510 Series, Speedhide Semi-gloss 6-500 Series.

Rodda, [Master Painter Semi-Gloss Enamel, 542101] [Metal Master DTM Enamel Semi-Gloss 548901]

Sherwin-Williams, Pro Industrial Zero VOC, B66-650 (0 g/l VOC)

Acrylic High Gloss Finish (Gloss Level 6): http://www.specifypaint.com/APL/paintinfo_APL/MpiNumber.asp?ID=114000

Benjamin Moore, Benjamin Moore, Super Spec HP DTM Acrylic Gloss P28. Ultra Spec 500 Interior Gloss Finish N540

Coronado Paint, Super Kote 5000 Acrylic High Gloss Enamel 414-101

Kelly-Moore, Dura-Poxy+ Gloss Acrylic Enamel 1680

Miller Paint Company, Acrimetal Int/Ext Latex Gloss Finish, 7300.

PPG Architectural Coatings, Speedhide Int /Ext 100% Acrylic Gloss 6-8534 Gloss.

Rodda, [Unique II Exterior/Interior Gloss Enamel, 552001] [Metal Master DTM Enamel Gloss 558901].

Sherwin Williams, [ProMar 200 Interior Latex Gloss Enamel, B21W201] [ProClassic, Waterborne Interior Gloss Enamel B21W51].


Dry-fall paint exposed to low temperatures and possible condensation at structural steel roof deck may fail by loss of adhesion. Glycol content in dry-fall paint reduces temperature resistance. Limit acceptance of dry-fall paint to manufacturers who can show low temperature adhesion to 40 degrees or less ambient and surface temperatures during application where this may be a factor to consider.


Interior Dry-Fall Coating at Interior Exposed-to-View Overhead Steel Surfaces (Including Decking and Framing): One coat application, self-priming, dry-fall, rust and corrosion resistant coating system. Apply additional coats as required to cover for uniform finish with no holidays.

Pre-Treatment and Primers: Not required.<verify coatings for 35 degrees F application temperatures, rust inhibitive, and self-priming>

Dryfall Coating:

Tnemec, Tnemec, Uni-Bond DF, Self-Crosslinking Waterborne Acrylic, Series 115.

[PPG Speedhide Super Tech 100% Acrylic, WB Dry Fog 6-723 Flat 724 Semi-gloss]


Following manufacturers are accepted where surface temperatures are expected to be 50 degrees or higher. Suitable steel decking at interior floor levels.


[Interior Dry-Fall Paint at Interior Exposed to View Overhead Surfaces not Exposed to Surface or Ambient Temperatures Below 50 degrees F: One coat application, waterborne, dry-fall paint system. Apply additional coats as required to cover for uniform finish with no holidays.

Pre-Treatment at Galvanized Surfaces / Field Applied Etching Cleaner: Use in lieu of SP-1 Solvent Cleaning, specified under preparation. http://www.specifypaint.com/APL/paintinfo_APL/MpiNumber.asp?ID=25000

Columbia Paint CGI, Jasco, Metal Etch 0700-0703.

Kelly-Moore Jasco, Metal Etch 0700-0703.

Diamond Vogel, Great Lakes Laboratories, Clean 'n Etch.

PPG Architectural Coatings, Prep 88 WB Heavy Duty Cleaner Concentrate

Rodda Paint, Henkel Amchem Galvaprep

Sherwin-Williams, Sherwin-Williams, Clean & Etch.

Spectra-Tone CGI, Jasco, Metal Etch 0700-0703.

Pre-Treatment at Ferrous Metal Primer: Conform to manufacturer’s instructions.

One or Two-Coat Dryfall Paint:

Benjamin Moore Super Spec DTM Sweep Up Spray 154.

Coronado: SuperKote 5000 Latex Dryfall Flat 110 Line.

Kelly-Moore, Dry Fog II Flat Latex Maintenance Finish 480

Miller: PPG Interior Dry Fog

PPG Architectural Coatings, PPG Speedhide Super Tech 100% Acrylic, WB Dry Fog 6-723 Flat.

[Rodda Paint, 100 Percent Acrylic Dryfall Flat, 513801.

VOCs: 102 grams/liter

Application Temperature: Min 50 degrees F

Solids: Volume = 42 percent / Weight = 62 percent]

Sherwin-Williams, Low VOC Waterborne Acrylic Dryfall B42 Series (34 g/L VOC).

Tnemec, Tnemec, Uni-Bond DF, Self-Crosslinking Waterborne Acrylic Series 115.

Interior Concrete Masonry Walls - Epoxy Finish - (Toilets and other Sanitary Areas):

Block Filler: As specified by this Section. http://www.specifypaint.com/APL/paintinfo_APL/MpiNumber.asp?ID=4000

Two-Coat, Waterborne Epoxy Finish – Semi-Gloss to Gloss Finish: http://www.specifypaint.com/APL/paintinfo_APL/MpiNumber.asp?ID=115000

Benjamin Moore, Super Spec Acrylic Epoxy Coating (256).

Coronado Paint, Waterborne Acrylic Epoxy 138 Line.

Kelly-Moore, Envira-Poxy Water-Reducible Epoxy Polyamide 7100.

Miller Paint Company, Waterborne Epoxy Semi-Gloss 4200/4440.

PPG Architectural Coatings, Pitt Glaze WB Acrylic Epoxy16-551 Semi-Gloss .

Rodda / Cloverdale, EcoLogic Waterborne Epoxy Semi-Gloss 70504.

Sherwin-Williams, Water Based Catalyzed Epoxy B70 Series.


Low odor / Low ultra low VOC paints are in green


Interior Gypsum Board, Wood, Concrete, Masonry, and Other Substrates – General Use:

Primer: As specified by this Section.

Two-Coat Acrylic Flat Finish (Gloss Level 1): [Low Odor Paint - Interior Gypsum Board, Plaster, and Primed Wood: Conform to MPI GPS-1-08 and GPS-2-08 with VOC Environmental Range (ER) of less than 11 g/l.]

Benjamin Moore, Ultra Spec 500 Interior Flat Finish N536 [Eco-Spec WB Flat Wall Finish, 373 <premium>].

Coronado Paint, Super Kote 5000 Flat Wall Paint 28 Line [Air Care Odorless Acrylic Flat 11226 Line]

Kelly-Moore, EZY-Coat Interior Latex Flat, 485 [Green Coat Interior Acrylic Flat Wall Paint, 2000][Enviro-Coat Interior Acrylic Flat Wall Paint, 1500<premium>]

Miller Paint Company, Premium Interior Flat, 3780 [Acro Pure Zero VOC, 6450].

PPG Architectural Coatings, Pure Performance Zero 6-411, Pure Performance 9-100.

Rodda, Master Painter, Interior Latex Flat, 513101 [Horizon Flat Zero VOC 513501].

Sherwin Williams, ProMar 200 Flat Latex, B30W200 [ProGreen 200 Low VOC] [Harmony Zero VOC Flat Finish, B5 Series<premium>]

Two-Coat Acrylic Velvet/Low Sheen Finish (Gloss Level 2): http://www.specifypaint.com/APL/paintinfo_APL/MpiNumber.asp?ID=44000

Two-Coat Acrylic Velvet/Low Sheen Finish (Gloss Level 2): Ceilings in public areas, including exposed to view wood ceilings [of structural insulated panels].

Benjamin Moore, Ultra Spec 500 Interior Low Sheen N537

Coronado Paint, Super Kote 5000 Interior Latex Eggshell 30 Line

Kelly-Moore, Styro-Cote Interior Acrylic Low Sheen Enamel 1007

Miller Paint Company, Premium Eggshell 3880

PPG Architectural Coatings, WallHide interior Flat 80-110.

Rodda Paint, Master Painter Pearl Luster 563101 / Master Painter Satin 523101

Sherwin Williams: ProMar 200 Zero VOC Eg-Shel B20-2600 (0 g/L VOC).

Two-Coat Acrylic Eggshell Finish (Gloss Level 3): Wall surfaces, including MDF baseboards, in public areas.

Benjamin Moore, Ultra Spec 500 Interior Eggshell Finish N538 Super Spec Latex Eggshell Enamel 274

Coronado Paint, Super Kote 5000 Latex Eggshell Enamel Air Care Odorless Acrylic Eggshell 1230 Line.

PPG Architectural Coatings, Speedhide Zero Eggshell 6-4310.

Kelly-Moore, Professional Interior Acrylic Eggshell Enamel 1010. [Green Coat Interior Acrylic 0 VOC Eggshell Enamel 2010.]

Miller Paint Company, Premium Eggshell, 3880 Acro Pure Zero VOC 4650.

Rodda, Lasyn Eggshell Enamel 533001. [Horizon Satin Zero VOC 523501(?)].

Sherwin Williams, Interior Latex Egg Shell, B20W8521. [ProMar 200 Zero VOC Eg-Shel B20-2600 (0 g/L VOC).]

Two-Coat Acrylic Satin Finish (Gloss Level 4): http://www.specifypaint.com/APL/paintinfo_APL/MpiNumber.asp?ID=43000

Benjamin Moore, Ultra Spec 500 Interior Semi-Gloss N539 Super Spec Latex Pearl Finish 277.

Coronado Paint, Super Kote 5000 Acrylic Satin Enamel

Kelly-Moore, Professional Acrylic Satin Enamel 1040.

Miller Paint Company, Premium Satin 4480.

PPG Architectural Coatings, Speedhide Interior Satin 6-3511 series

Rodda, Unique II Acrylic Enamel Low Gloss 532001

Sherwin Williams: ProMar 200, Interior Latex Semi-Gloss.

Two-Coat Acrylic Semi-Gloss Finish (Gloss Level 5): Include gypsum board walls and ceilings of areas subject to moisture such as toilet rooms, janitor closets, and other utility areas subject to indirect moisture exposure and wood trim. http://www.specifypaint.com/APL/paintinfo_APL/MpiNumber.asp?ID=54000 [http://www.specifypaint.com/APL/paintinfo_APL/MpiNumber.asp?ID=147000]

Benjamin Moore, Ultra Spec 500 Gloss Finish N540 Super Spec Latex Semi-Gloss Enamel, 276

Coronado Paint, Super Kote 5000 Acrylic Semi-Gloss Enamel 32 Line [Air Care Odorless Acrylic Semi-gloss Enamel 926 Line].

Kelly-Moore, Professional Interior Acrylic Semi-Gloss Enamel, KM 1050 [Green Coat Interior Acrylic Semi-Gloss 2020].

Miller Paint Company, Premium Semi-Gloss 4580 [Acro PureZero VOC 6150].

PPG Architectural Coatings, Speed Hide Zero 6-4501 Semi-Gloss.

Rodda / Cloverdale, Unique II Semi-Gloss Enamel 542001.

Sherwin-Williams, ProMar 200 Semi-Gloss B31W200 Zero VOC Semi-Gloss B31-2600 (0 g/L VOC).

Interior Gypsum Board – Deep Tone/High Pigmented Decorative Colors: Abrasive resistant.

Foundation Coat:

Benjamin Moore, AURA Color Foundation, Waterborne Acrylic 521.

Two Coat 100 Percent Acrylic Latex, Eggshell/Low Sheen Burnish-Resistant Finish:

Benjamin Moore, AURA, Waterborne Acrylic Interior Paint [522 Matt] [524 Eggshell] [528 Semi-Gloss].

Interior Gypsum Board - Utility Areas (Tile-Like Finish): Includes walls and ceilings of areas subject to direct moisture/wetting exposure, including at kitchen, toilet rooms, janitor closets, and other utility areas.

Epoxy Primer/Sealer: As specified by this Section.

Two-Coat, Waterborne Epoxy Finish (Gloss Level 6):

Benjamin Moore, Super Spec Acrylic Epoxy Coating 256

Coronado Paint, Coropoxy Waterborne Epoxy Gloss or Semi-Gloss 138 Line

Kelly-Moore, Envira-Poxy Water-Reducible Epoxy Polyamide 7100.

Miller Paint Company, Waterborne Epoxy Semi-Gloss 4200/4440.

PPG Architectural Coatings, Pitt Glaze WB Epoxy 16-551 Series

Rodda Paint, Cloverdale Ecologic WB Epoxy Gloss, 70503.

Sherwin-Williams, Pro Industrial Zero VOC WB Epoxy B73-300 Series (0 g/L VOC).


Consider an epoxy or other more durable finish for concrete floors. Painted concrete floors are suitable for light to medium pedestrian traffic in most cases. Few manufacturers are included in for this system.


Interior Concrete Floors: Two-Coat Acrylic Finish (Gloss Level 5-6). http://www.specifypaint.com/APL/paintinfo_APL/MpiNumber.asp?ID=68000

Benjamin Moore, Moore’s Latex Floor & Patio Enamel C122.

Coronado Paint, Tough Shield Acrylic Floor & Patio Coating 52 Line.

Kelly-Moore, Dura-Poxy+ 100% Acrylic Porch & Floor Eggshell Enamel 1786.

Miller Paint Company, Tuff Tread 280.

PPG Architectural Coatings, Floor and Porch WB Alkyd Gloss 3-610.

Rodda / Cloverdale Paint, Tuff Deck Acrylic Floor Finish 527501.

Sherwin-Williams, Armorseal Tread-Plex, 100 percent Water Based Floor Coating B90 Series.

Tnemec, Tneme-Tread, Series 287, acrylic epoxy.

Interior Clear Transparent Finished Wood: Three-Coat Finish. Sanding sealer and Stain as instructed by manufacturer to match Architect’s sample.

Varnish - Clear, Waterborne, Satin (Gloss Level 4):

Benjamin Moore, Benwood Stays Clear, Satin 423.

Coronado Paint, Aqua Plastic WB Acrylic Urethane Satin 70-270

Kelly-Moore, Kel-Thane II Waterborne Interior Clear Satin Finish 2097.

Miller Paint Company, Acriclear - Acrylic Urethane Satin Varnish 1225.

PPG Architectural Coatings, Olympic Premium WB Polyurethane Clear 42784 or Wood Pride Water Based Satin Varnish 1802.

Rodda/Cloverdale, Timberlox Interior Waterborne Alkyd Satin 59314.

Sherwin-Williams, Minwax Polycrylic Protective Finish Satin 3333 (275 g/L VOC)

Varnish - Clear, Waterborne, Semi-Gloss (Gloss Level 5):

Benjamin Moore, NA

Coronado Paint, Aqua Plastic WB Acrylic Urethane Semi-Gloss 70-100

Kelly-Moore, Kel-Thane II Waterborne Interior Clear SG Finish 2094.

Miller Paint Company, AcriClear Waterborne Polyurethane Satin 1225.

PPG Architectural Coatings, Olympic Premium WB Polyurethane Clear 42786 or Wood Pride Water Based Satin Varnish, 1808.

Rodda / Cloverdale, Timberlox Interior Waterborne Acrylic Sanding Sealer 42114 / Timberlox Interior Waterborne Acrylic Varnish Satin 42314.

Sherwin-Williams, Minwax Polycrylic Protective Finish Semi-Gloss 4444.

Inside of Ducts, Where Visible from Room:

Same treatment as specified for galvanized and ferrous metal surfaces.

Two-Coat Acrylic Flat Finish: As specified this Section for each materials. Dull black color.

Exposed Registers, Grilles, Exposed Conduit, Electric Cabinets, and Unfinished Portions of Cast-iron Fixtures Exposed to View:

Same treatments as specified for applicable materials.

Acrylic Finish Coat: As specified this Section for each materials. Match adjacent surfaces.

END OF SECTION